X-Git-Url: https://git.madduck.net/etc/awesome.git/blobdiff_plain/4003d0963948f857fe53534b876ac9defe7e3fec..ca11d6acbea616cefabaf376d8d38b9a364958f0:/widgets/bat.lua diff --git a/widgets/bat.lua b/widgets/bat.lua index 069fac8..ec9a289 100644 --- a/widgets/bat.lua +++ b/widgets/bat.lua @@ -19,6 +19,7 @@ local math = { abs = math.abs, min = math.min } local string = { format = string.format } +local type = type local tonumber = tonumber local setmetatable = setmetatable @@ -69,6 +70,7 @@ local function worker(args) local sum_rate_current = 0 local sum_rate_voltage = 0 local sum_rate_power = 0 + local sum_rate_energy = 0 local sum_energy_now = 0 local sum_energy_full = 0 local sum_energy_percentage = 0 @@ -98,11 +100,12 @@ local function worker(args) bat_now.n_status[i] = first_line(bstr .. "/status") or "N/A" sum_rate_current = sum_rate_current + (rate_current or 0) - sum_rate_voltage = sum_rate_voltage + rate_voltage - sum_rate_power = sum_rate_power + (rate_power or ((rate_voltage * rate_current) / 1e6)) + sum_rate_voltage = sum_rate_voltage + (rate_voltage or 0) + sum_rate_power = sum_rate_power + (rate_power or 0) + sum_rate_energy = sum_rate_energy + (rate_power or (((rate_voltage or 0) * (rate_current or 0)) / 1e6)) sum_energy_now = sum_energy_now + (energy_now or 0) - sum_energy_full = sum_energy_full + energy_full - sum_energy_percentage = sum_energy_percentage + energy_percentage + sum_energy_full = sum_energy_full + (energy_full or 0) + sum_energy_percentage = sum_energy_percentage + (energy_percentage or 0) end end @@ -111,25 +114,26 @@ local function worker(args) if bat_now.status ~= "N/A" then -- update {perc,time,watt} iff battery not full and rate > 0 - if bat_now.status ~= "Full" and (sum_rate_current > 0 or sum_rate_power > 0) then + if bat_now.status ~= "Full" and (sum_rate_power > 0 or sum_rate_current > 0) then local rate_time = 0 + local div = (sum_rate_power > 0 and sum_rate_power) or sum_rate_current if bat_now.status == "Charging" then - rate_time = (sum_energy_full - sum_energy_now) / (sum_rate_power or sum_rate_current) + rate_time = (sum_energy_full - sum_energy_now) / div else -- Discharging - rate_time = sum_energy_now / (sum_rate_power or sum_rate_current) + rate_time = sum_energy_now / div end - if rate_time < 0.01 then -- check for magnitude discrepancies + if rate_time < 0.01 then -- check for magnitude discrepancies (#199) rate_time_magnitude = math.abs(math.floor(math.log10(rate_time))) rate_time = rate_time * 10^(rate_time_magnitude - 2) end local hours = math.floor(rate_time) local minutes = math.floor((rate_time - hours) * 60) - bat_now.perc = tonumber(string.format("%d", math.min(100, sum_energy_percentage / #batteries))) + bat_now.perc = tonumber(string.format("%d", math.floor(math.min(100, sum_energy_percentage / #batteries)))) bat_now.time = string.format("%02d:%02d", hours, minutes) - bat_now.watt = tonumber(string.format("%.2f", sum_rate_power / 1e6)) + bat_now.watt = tonumber(string.format("%.2f", sum_rate_energy / 1e6)) elseif bat_now.status == "Full" then bat_now.perc = 100 bat_now.time = "00:00" @@ -141,7 +145,7 @@ local function worker(args) settings() -- notifications for low and critical states - if notify == "on" and bat_now.perc and bat_now.status == "Discharging" then + if notify == "on" and type(bat_now.perc) == "number" and bat_now.status == "Discharging" then if bat_now.perc <= 5 then bat.id = naughty.notify({ preset = bat_notification_critical_preset,