X-Git-Url: https://git.madduck.net/etc/awesome.git/blobdiff_plain/82dd3effca595595b8b6183992d70a31afb20f03..fbc8c2ba7b6b250b7919ef9bb311ab2719ecfd10:/widgets/bat.lua?ds=sidebyside diff --git a/widgets/bat.lua b/widgets/bat.lua index 789c694..56bba23 100644 --- a/widgets/bat.lua +++ b/widgets/bat.lua @@ -15,47 +15,72 @@ local wibox = require("wibox") local math = { floor = math.floor } local string = { format = string.format } +local tonumber = tonumber local setmetatable = setmetatable -- Battery infos -- lain.widgets.bat -local bat = {} local function worker(args) - local args = args or {} - local timeout = args.timeout or 30 - local battery = args.battery or "BAT0" + local bat = {} + local args = args or {} + local timeout = args.timeout or 30 + local battery = args.battery or "BAT0" + local ac = args.ac or "AC0" + local notify = args.notify or "on" local settings = args.settings or function() end bat.widget = wibox.widget.textbox('') + bat_notification_low_preset = { + title = "Battery low", + text = "Plug the cable!", + timeout = 15, + fg = "#202020", + bg = "#CDCDCD" + } + + bat_notification_critical_preset = { + title = "Battery exhausted", + text = "Shutdown imminent", + timeout = 15, + fg = "#000000", + bg = "#FFFFFF" + } + function update() bat_now = { - status = "Not present", - perc = "N/A", - time = "N/A", - watt = "N/A" + status = "Not present", + ac_status = "N/A", + perc = "N/A", + time = "N/A", + watt = "N/A" } - local bstr = "/sys/class/power_supply/" .. battery - + local bstr = "/sys/class/power_supply/" .. battery local present = first_line(bstr .. "/present") if present == "1" then - local rate = first_line(bstr .. "/power_now") or - first_line(bstr .. "/current_now") + local rate = tonumber(first_line(bstr .. "/power_now")) + local current_now = false + + if not rate then + rate = tonumber(first_line(bstr .. "/current_now")) + current_now = true + end - local ratev = first_line(bstr .. "/voltage_now") + local ratev = tonumber(first_line(bstr .. "/voltage_now")) - local rem = first_line(bstr .. "/energy_now") or - first_line(bstr .. "/charge_now") + local rem = tonumber(first_line(bstr .. "/energy_now") or + first_line(bstr .. "/charge_now")) - local tot = first_line(bstr .. "/energy_full") or - first_line(bstr .. "/charge_full") + local tot = tonumber(first_line(bstr .. "/energy_full") or + first_line(bstr .. "/charge_full")) bat_now.status = first_line(bstr .. "/status") or "N/A" + bat_now.ac = first_line(string.format("/sys/class/power_supply/%s/online", ac)) or "N/A" local time_rat = 0 if bat_now.status == "Charging" @@ -67,52 +92,56 @@ local function worker(args) end local hrs = math.floor(time_rat) - local min = (time_rat - hrs) * 60 + if hrs < 0 then hrs = 0 elseif hrs > 23 then hrs = 23 end + + local min = math.floor((time_rat - hrs) * 60) + if min < 0 then min = 0 elseif min > 59 then min = 59 end bat_now.time = string.format("%02d:%02d", hrs, min) - bat_now.perc = (rem / tot) * 100 - bat_now.watt = string.format("%.2fW", (rate * ratev) / 1e12) - -- notifications for low and critical states - if bat_new.status == "Discharging" - then - if bat_now.perc <= 5 - then - bat.id = naughty.notify({ - text = "shutdown imminent", - title = "battery nearly exhausted", - position = "top_right", - timeout = 15, - fg="#000000", - bg="#ffffff", - ontop = true, - replaces_id = bat.id - }).id - elseif bat_now.perc <= 15 - then - bat.id = naughty.notify({ - text = "plug the cable", - title = "battery low", - position = "top_right", - timeout = 15, - fg="#202020", - bg="#cdcdcd", - ontop = true, - replaces_id = bat.id - }).id - end + local perc = tonumber(first_line(bstr .. "/capacity")) or math.floor((rem / tot) * 100) + + if perc <= 100 then + bat_now.perc = string.format("%d", perc) + elseif perc > 100 then + bat_now.perc = "100" + elseif perc < 0 then + bat_now.perc = "0" end - bat_now.perc = string.format("%d", bat_now.perc) + if current_now then + bat_now.watt = string.format("%.2fW", (rate * ratev) / 1e12) + else + bat_now.watt = string.format("%.2fW", rate) + end end widget = bat.widget settings() + + -- notifications for low and critical states + if bat_now.status == "Discharging" and notify == "on" and bat_now.perc + then + local nperc = tonumber(bat_now.perc) or 100 + if nperc <= 5 + then + bat.id = naughty.notify({ + preset = bat_notification_critical_preset, + replaces_id = bat.id, + }).id + elseif nperc <= 15 + then + bat.id = naughty.notify({ + preset = bat_notification_low_preset, + replaces_id = bat.id, + }).id + end + end end - newtimer("bat", timeout, update) + newtimer(battery, timeout, update) - return bat.widget + return setmetatable(bat, { __index = bat.widget }) end -return setmetatable(bat, { __call = function(_, ...) return worker(...) end }) +return setmetatable({}, { __call = function(_, ...) return worker(...) end })