]> git.madduck.net Git - etc/awesome.git/commitdiff

madduck's git repository

Every one of the projects in this repository is available at the canonical URL git://git.madduck.net/madduck/pub/<projectpath> — see each project's metadata for the exact URL.

All patches and comments are welcome. Please squash your changes to logical commits before using git-format-patch and git-send-email to patches@git.madduck.net. If you'd read over the Git project's submission guidelines and adhered to them, I'd be especially grateful.

SSH access, as well as push access can be individually arranged.

If you use my repositories frequently, consider adding the following snippet to ~/.gitconfig and using the third clone URL listed for each project:

[url "git://git.madduck.net/madduck/"]
  insteadOf = madduck:

pull #201 fixes
authorLuke Bonham <dada@archlinux.info>
Tue, 31 May 2016 08:44:51 +0000 (10:44 +0200)
committerLuke Bonham <dada@archlinux.info>
Tue, 31 May 2016 08:44:51 +0000 (10:44 +0200)
widgets/bat.lua

index e1bc5d1133839104653b53494da8e9f0ec0b645c..5f049e204d55626776fa2aad051692370054dada 100644 (file)
@@ -29,7 +29,7 @@ local function worker(args)
     local batteries = args.batteries or (args.battery and {args.battery}) or {"BAT0"}
     local ac        = args.ac or "AC0"
     local notify    = args.notify or "on"
-    local settings = args.settings or function() end
+    local settings  = args.settings or function() end
 
     bat.widget = wibox.widget.textbox('')
 
@@ -58,6 +58,11 @@ local function worker(args)
             watt      = "N/A"
         }
 
+        bat_now.n_status = {}
+        for i = 1, #batteries do
+            bat_now.n_status[i] = "Not present"
+        end
+
         local sum_rate_current = 0
         local sum_rate_voltage = 0
         local sum_rate_power = 0
@@ -87,28 +92,29 @@ local function worker(args)
                 local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
                                           math.floor((energy_now / energy_full) * 100)
 
-                if bat_now.status ~= "Charging" and bat_now.status ~= "Discharging"
+                if bat_now.n_status[i] ~= "Charging" and bat_now.n_status[i] ~= "Discharging"
                 then
-                    bat_now.status = first_line(bstr .. "/status") or "N/A"
+                    bat_now.n_status[i] = first_line(bstr .. "/status") or "N/A"
                 end
 
-                sum_rate_current = sum_rate_current + (rate_current or 0)
-                sum_rate_voltage = sum_rate_voltage + rate_voltage
-                sum_rate_power = sum_rate_power + (rate_power or ((rate_voltage * rate_current) / 1e6))
-                sum_energy_now = sum_energy_now + energy_now
-                sum_energy_full = sum_energy_full + energy_full
+                sum_rate_current      = sum_rate_current + (rate_current or 0)
+                sum_rate_voltage      = sum_rate_voltage + rate_voltage
+                sum_rate_power        = sum_rate_power + (rate_power or ((rate_voltage * rate_current) / 1e6))
+                sum_energy_now        = sum_energy_now + energy_now
+                sum_energy_full       = sum_energy_full + energy_full
                 sum_energy_percentage = sum_energy_percentage + energy_percentage
             end
         end
 
-        local astr    = "/sys/class/power_supply/" .. ac
-        bat_now.ac_status = first_line(astr .. "/online") or "N/A"
+        bat_now.status = bat_now.n_status[1]
+        bat_now.ac_status = first_line(string.format("/sys/class/power_supply/%s/online", ac)) or "N/A"
 
         -- update {perc,time,watt} iff rate > 0 and battery not full
-        if ((sum_rate_current > 0) or (sum_rate_power > 0))
-            and bat_now.status ~= "N/A" and bat_now.status ~= "Full"
+        if (sum_rate_current > 0 or sum_rate_power > 0)
+           and bat_now.status ~= "N/A" and bat_now.status ~= "Full"
         then
             local rate_time = 0
+
             if bat_now.status == "Charging" then
                 rate_time = (sum_energy_full - sum_energy_now) / (sum_rate_power or sum_rate_current)
             elseif bat_now.status == "Discharging" then
@@ -118,7 +124,8 @@ local function worker(args)
             local hours   = math.floor(rate_time)
             local minutes = math.floor((rate_time - hours) * 60)
             local watt    = sum_rate_power / 1e6
-            bat_now.perc  = string.format("%d", math.min(100, sum_energy_percentage / table.getn(batteries)))
+
+            bat_now.perc  = string.format("%d", math.min(100, sum_energy_percentage / #batteries))
             bat_now.time  = string.format("%02d:%02d", hours, minutes)
             bat_now.watt  = string.format("%.2fW", watt)
         end