]> git.madduck.net Git - etc/awesome.git/blob - widgets/bat.lua

madduck's git repository

Every one of the projects in this repository is available at the canonical URL git://git.madduck.net/madduck/pub/<projectpath> — see each project's metadata for the exact URL.

All patches and comments are welcome. Please squash your changes to logical commits before using git-format-patch and git-send-email to patches@git.madduck.net. If you'd read over the Git project's submission guidelines and adhered to them, I'd be especially grateful.

SSH access, as well as push access can be individually arranged.

If you use my repositories frequently, consider adding the following snippet to ~/.gitconfig and using the third clone URL listed for each project:

[url "git://git.madduck.net/madduck/"]
  insteadOf = madduck:

61ad6a33ebb5b8a722e18d5329887fe81b1741c6
[etc/awesome.git] / widgets / bat.lua
1
2 --[[
3                                                                                                   
4          Licensed under GNU General Public License v2 
5           * (c) 2013,      Luke Bonham                
6           * (c) 2010-2012, Peter Hofmann              
7                                                                                                   
8 --]]
9
10 local newtimer     = require("lain.helpers").newtimer
11 local first_line   = require("lain.helpers").first_line
12
13 local naughty      = require("naughty")
14 local wibox        = require("wibox")
15
16 local math         = { floor  = math.floor }
17 local string       = { format = string.format }
18 local tonumber     = tonumber
19
20 local setmetatable = setmetatable
21
22 -- Battery infos
23 -- lain.widgets.bat
24
25 local function worker(args)
26         local bat      = {}
27         local args     = args or {}
28         local timeout  = args.timeout or 30
29         local battery  = args.battery or "BAT0"
30         local ac       = args.ac or "AC0"
31         local notify   = args.notify or "on"
32         local settings = args.settings or function() end
33
34         bat.widget = wibox.widget.textbox('')
35
36         bat_notification_low_preset = {
37                 title = "Battery low",
38                 text = "Plug the cable!",
39                 timeout = 15,
40                 fg = "#202020",
41                 bg = "#CDCDCD"
42         }
43
44         bat_notification_critical_preset = {
45                 title = "Battery exhausted",
46                 text = "Shutdown imminent",
47                 timeout = 15,
48                 fg = "#000000",
49                 bg = "#FFFFFF"
50         }
51
52         function update()
53                 bat_now = {
54                         status    = "Not present",
55                         ac_status = "N/A",
56                         perc      = "N/A",
57                         time      = "N/A",
58                         watt      = "N/A"
59                 }
60
61                 local bstr    = "/sys/class/power_supply/" .. battery
62                 local astr    = "/sys/class/power_supply/" .. ac
63                 local present = first_line(bstr .. "/present")
64
65                 if present == "1"
66                 then
67                         -- current_now(I)[uA], voltage_now(U)[uV], power_now(P)[uW]
68                         local rate_current      = tonumber(first_line(bstr .. "/current_now"))
69                         local rate_voltage      = tonumber(first_line(bstr .. "/voltage_now"))
70                         local rate_power        = tonumber(first_line(bstr .. "/power_now"))
71
72                         -- energy_now(P)[uWh], charge_now(I)[uAh] 
73                         local energy_now        = tonumber(first_line(bstr .. "/energy_now") or
74                                                                                 first_line(bstr .. "/charge_now"))
75                                                   
76                         -- energy_full(P)[uWh], charge_full(I)[uAh],                       
77                         local energy_full       = tonumber(first_line(bstr .. "/energy_full") or
78                                                                                 first_line(bstr .. "/charge_full"))
79
80
81                         local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
82                                                                                 math.floor((energy_now / energy_full) * 100)
83
84                         bat_now.status = first_line(bstr .. "/status") or "N/A"
85                         bat_now.ac_status     = first_line(astr .. "/online") or "N/A"
86
87                         -- if rate = 0 or rate not defined skip the round
88                         if      not (rate_power and rate_power > 0) and
89                                 not (rate_current and  rate_current > 0) and
90                                 not (bat_now.status == "Full")
91                         then
92                                 return
93                         end
94                         
95                         local rate_time = 0
96                         if bat_now.status == "Charging"
97                         then
98                                 rate_time = (energy_full - energy_now) / rate_power or rate_current
99                         elseif bat_now.status == "Discharging"
100                         then
101                                 rate_time = energy_now / rate_power or rate_current
102                         end
103
104                         local hours   = math.floor(rate_time)
105                         local minutes = math.floor((rate_time - hours) * 60)
106
107                         bat_now.perc = string.format("%d", energy_percentage)
108                         bat_now.time = string.format("%02d:%02d", hours, minutes)
109                         bat_now.watt = string.format("%.2fW", rate_power / 1e6 or (rate_voltage * rate_current)  / 1e12)
110                 
111                 end
112                 widget = bat.widget
113                 settings()
114
115                 -- notifications for low and critical states
116                 if bat_now.status == "Discharging" and notify == "on" and bat_now.perc
117                 then
118                         local nperc = tonumber(bat_now.perc) or 100
119                         if nperc <= 5
120                         then
121                                 bat.id = naughty.notify({
122                                         preset = bat_notification_critical_preset,
123                                         replaces_id = bat.id,
124                                 }).id
125                         elseif nperc <= 15
126                         then
127                                 bat.id = naughty.notify({
128                                         preset = bat_notification_low_preset,
129                                         replaces_id = bat.id,
130                                 }).id
131                         end
132                 end
133         end
134
135         newtimer(battery, timeout, update)
136
137         return setmetatable(bat, { __index = bat.widget })
138 end
139
140 return setmetatable({}, { __call = function(_, ...) return worker(...) end })