]> git.madduck.net Git - etc/awesome.git/blobdiff - widgets/bat.lua

madduck's git repository

Every one of the projects in this repository is available at the canonical URL git://git.madduck.net/madduck/pub/<projectpath> — see each project's metadata for the exact URL.

All patches and comments are welcome. Please squash your changes to logical commits before using git-format-patch and git-send-email to patches@git.madduck.net. If you'd read over the Git project's submission guidelines and adhered to them, I'd be especially grateful.

SSH access, as well as push access can be individually arranged.

If you use my repositories frequently, consider adding the following snippet to ~/.gitconfig and using the third clone URL listed for each project:

[url "git://git.madduck.net/madduck/"]
  insteadOf = madduck:

fixing parethesis issue
[etc/awesome.git] / widgets / bat.lua
index 8cc1ea923d21668708c3ccd4f43df924309a78ba..13916410d2757689e37f078d603d6cfd075a5d9e 100644 (file)
@@ -34,19 +34,19 @@ local function worker(args)
        bat.widget = wibox.widget.textbox('')
 
        bat_notification_low_preset = {
-               title = "Battery low",
-               text = "Plug the cable!",
+        title   = "Battery low",
+               text    = "Plug the cable!",
                timeout = 15,
-               fg = "#202020",
-               bg = "#CDCDCD"
+               fg      = "#202020",
+               bg      = "#CDCDCD"
        }
 
        bat_notification_critical_preset = {
-               title = "Battery exhausted",
-               text = "Shutdown imminent",
+               title   = "Battery exhausted",
+               text    = "Shutdown imminent",
                timeout = 15,
-               fg = "#000000",
-               bg = "#FFFFFF"
+               fg      = "#000000",
+               bg      = "#FFFFFF"
        }
 
        function update()
@@ -69,60 +69,58 @@ local function worker(args)
                        local rate_voltage      = tonumber(first_line(bstr .. "/voltage_now"))
                        local rate_power        = tonumber(first_line(bstr .. "/power_now"))
 
-                       -- if rate = 0 or rate not defined skip the round
-                       if not (rate_power and rate_power > 0) and 
-                               not (rate_current and  rate_current > 0) 
-                       then
-                               return 
-                       end
-
-                       -- energy_now(P)[uWh], charge_now(I)[uAh] 
+                       -- energy_now(P)[uWh], charge_now(I)[uAh]
                        local energy_now        = tonumber(first_line(bstr .. "/energy_now") or
-                                                                               first_line(bstr .. "/charge_now"))
-                                                 
-                       -- energy_full(P)[uWh], charge_full(I)[uAh],                       
+                                      first_line(bstr .. "/charge_now"))
+
+                       -- energy_full(P)[uWh], charge_full(I)[uAh],
                        local energy_full       = tonumber(first_line(bstr .. "/energy_full") or
-                                                                               first_line(bstr .. "/charge_full"))
+                                      first_line(bstr .. "/charge_full"))
 
 
                        local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
-                                                                               math.floor((energy_now / energy_full) * 100)
+                                      math.floor((energy_now / energy_full) * 100)
 
-                       bat_now.status = first_line(bstr .. "/status") or "N/A"
-                       bat_now.ac_status     = first_line(astr .. "/online") or "N/A"
+                       bat_now.status    = first_line(bstr .. "/status") or "N/A"
+                       bat_now.ac_status = first_line(astr .. "/online") or "N/A"
 
-                       local rate_time = 0
-                       if bat_now.status == "Charging"
-                       then
-                               rate_time = (energy_full - energy_now) / rate_power or rate_current
-                       elseif bat_now.status == "Discharging"
+                       -- if rate = 0 or rate not defined skip the round
+                       if      not (rate_power and rate_power > 0) and
+                               not (rate_current and  rate_current > 0) and
+                               not (bat_now.status == "Full")
                        then
-                               rate_time = energy_now / rate_power or rate_current
+                               return
+                       end
+
+                       local rate_time = 0
+                       if bat_now.status == "Charging" then
+                           rate_time = (energy_full - energy_now) / (rate_power or rate_current)
+                       elseif bat_now.status == "Discharging" then
+                           rate_time = energy_now / (rate_power or rate_current)
                        end
 
                        local hours   = math.floor(rate_time)
                        local minutes = math.floor((rate_time - hours) * 60)
-
+                        
+                        local watt    = rate_power and (rate_power / 1e6) or (rate_voltage * rate_current) / 1e12
+                        
                        bat_now.perc = string.format("%d", energy_percentage)
                        bat_now.time = string.format("%02d:%02d", hours, minutes)
-                       bat_now.watt = string.format("%.2fW", rate_power / 1e6 or (rate_voltage * rate_current)  / 1e12)
-               
+                       bat_now.watt = string.format("%.2fW", watt)
                end
+
                widget = bat.widget
                settings()
 
                -- notifications for low and critical states
-               if bat_now.status == "Discharging" and notify == "on" and bat_now.perc
-               then
+               if bat_now.status == "Discharging" and notify == "on" and bat_now.perc then
                        local nperc = tonumber(bat_now.perc) or 100
-                       if nperc <= 5
-                       then
+                       if nperc <= 5 then
                                bat.id = naughty.notify({
                                        preset = bat_notification_critical_preset,
                                        replaces_id = bat.id,
                                }).id
-                       elseif nperc <= 15
-                       then
+                       elseif nperc <= 15 then
                                bat.id = naughty.notify({
                                        preset = bat_notification_low_preset,
                                        replaces_id = bat.id,