]> git.madduck.net Git - etc/awesome.git/blobdiff - widgets/bat.lua

madduck's git repository

Every one of the projects in this repository is available at the canonical URL git://git.madduck.net/madduck/pub/<projectpath> — see each project's metadata for the exact URL.

All patches and comments are welcome. Please squash your changes to logical commits before using git-format-patch and git-send-email to patches@git.madduck.net. If you'd read over the Git project's submission guidelines and adhered to them, I'd be especially grateful.

SSH access, as well as push access can be individually arranged.

If you use my repositories frequently, consider adding the following snippet to ~/.gitconfig and using the third clone URL listed for each project:

[url "git://git.madduck.net/madduck/"]
  insteadOf = madduck:

alsa: added card, channel to widget table
[etc/awesome.git] / widgets / bat.lua
index 09b135fc29bc03463a411471c592b91430f6fa77..572d099266ad2683bf6890f7e3682ef9546523ff 100644 (file)
@@ -15,6 +15,7 @@ local wibox        = require("wibox")
 
 local math         = { floor  = math.floor }
 local string       = { format = string.format }
 
 local math         = { floor  = math.floor }
 local string       = { format = string.format }
+local tonumber     = tonumber
 
 local setmetatable = setmetatable
 
 
 local setmetatable = setmetatable
 
@@ -26,10 +27,27 @@ local function worker(args)
     local args = args or {}
     local timeout = args.timeout or 30
     local battery = args.battery or "BAT0"
     local args = args or {}
     local timeout = args.timeout or 30
     local battery = args.battery or "BAT0"
+    local notify = args.notify or "on"
     local settings = args.settings or function() end
 
     bat.widget = wibox.widget.textbox('')
 
     local settings = args.settings or function() end
 
     bat.widget = wibox.widget.textbox('')
 
+    bat_notification_low_preset = {
+        title = "Battery low",
+        text = "Plug the cable!",
+        timeout = 15,
+        fg = "#202020",
+        bg = "#CDCDCD"
+    }
+
+    bat_notification_critical_preset = {
+        title = "Battery exhausted",
+        text = "Shutdown imminent",
+        timeout = 15,
+        fg = "#000000",
+        bg = "#FFFFFF"
+    }
+
     function update()
         bat_now = {
             status = "Not present",
     function update()
         bat_now = {
             status = "Not present",
@@ -38,27 +56,29 @@ local function worker(args)
             watt   = "N/A"
         }
 
             watt   = "N/A"
         }
 
-        local present = first_line("/sys/class/power_supply/"
-                                   .. battery
-                                   .. "/present")
+        local bstr  = "/sys/class/power_supply/" .. battery
+
+        local present = first_line(bstr .. "/present")
 
         if present == "1"
         then
 
         if present == "1"
         then
-            local rate = first_line("/sys/class/power_supply/"
-                                    .. battery ..
-                                    "/power_now")
-            local ratev = first_line("/sys/class/power_supply/"
-                                    .. battery ..
-                                     "/voltage_now")
-            local rem = first_line("/sys/class/power_supply/"
-                                    .. battery ..
-                                   "/energy_now")
-            local tot = first_line("/sys/class/power_supply/"
-                                    .. battery ..
-                                   "/energy_full")
-            bat_now.status = first_line("/sys/class/power_supply/"
-                                    .. battery ..
-                                   "/status")
+            local rate  = first_line(bstr .. "/power_now") or
+                          first_line(bstr .. "/current_now")
+
+            local ratev = first_line(bstr .. "/voltage_now")
+
+            local rem   = first_line(bstr .. "/energy_now") or
+                          first_line(bstr .. "/charge_now")
+
+            local tot   = first_line(bstr .. "/energy_full") or
+                          first_line(bstr .. "/charge_full")
+
+            bat_now.status = first_line(bstr .. "/status") or "N/A"
+
+            rate  = tonumber(rate) or 1
+            ratev = tonumber(ratev)
+            rem   = tonumber(rem)
+            tot   = tonumber(tot)
 
             local time_rat = 0
             if bat_now.status == "Charging"
 
             local time_rat = 0
             if bat_now.status == "Charging"
@@ -70,44 +90,55 @@ local function worker(args)
             end
 
             local hrs = math.floor(time_rat)
             end
 
             local hrs = math.floor(time_rat)
-            local min = (time_rat - hrs) * 60
+            if hrs < 0 then hrs = 0 elseif hrs > 23 then hrs = 23 end
+
+            local min = math.floor((time_rat - hrs) * 60)
+            if min < 0 then min = 0 elseif min > 59 then min = 59 end
 
             bat_now.time = string.format("%02d:%02d", hrs, min)
 
             bat_now.time = string.format("%02d:%02d", hrs, min)
-            bat_now.perc = (rem / tot) * 100
-            bat_now.watt = string.format("%.2fW", (rate * ratev) / 1e12)
 
 
-            -- notifications for low and critical states
-            if bat_now.perc <= 5
+            bat_now.perc = first_line(bstr .. "/capacity")
+
+            if not bat_now.perc then
+                local perc = (rem / tot) * 100
+                if perc <= 100 then
+                    bat_now.perc = string.format("%d", perc)
+                elseif perc > 100 then
+                    bat_now.perc = "100"
+                elseif perc < 0 then
+                    bat_now.perc = "0"
+                end
+            end
+
+            if rate ~= nil and ratev ~= nil then
+                bat_now.watt = string.format("%.2fW", (rate * ratev) / 1e12)
+            else
+                bat_now.watt = "N/A"
+            end
+
+        end
+
+        widget = bat.widget
+        settings()
+
+        -- notifications for low and critical states
+        if bat_now.status == "Discharging" and notify == "on" and bat_now.perc ~= nil
+        then
+            local nperc = tonumber(bat_now.perc) or 100
+            if nperc <= 5
             then
                 bat.id = naughty.notify({
             then
                 bat.id = naughty.notify({
-                    text = "shutdown imminent",
-                    title = "battery nearly exhausted",
-                    position = "top_right",
-                    timeout = 15,
-                    fg="#000000",
-                    bg="#ffffff",
-                    ontop = true,
-                    replaces_id = bat.id
+                    preset = bat_notification_critical_preset,
+                    replaces_id = bat.id,
                 }).id
                 }).id
-            elseif bat.perc <= 15
+            elseif nperc <= 15
             then
                 bat.id = naughty.notify({
             then
                 bat.id = naughty.notify({
-                    text = "plug the cable",
-                    title = "battery low",
-                    position = "top_right",
-                    timeout = 15,
-                    fg="#202020",
-                    bg="#cdcdcd",
-                    ontop = true,
-                    replaces_id = bat.id
+                    preset = bat_notification_low_preset,
+                    replaces_id = bat.id,
                 }).id
             end
                 }).id
             end
-
-            bat_now.perc = string.format("%d", bat_now.perc)
         end
         end
-
-        widget = bat.widget
-        settings()
     end
 
     newtimer("bat", timeout, update)
     end
 
     newtimer("bat", timeout, update)