]> git.madduck.net Git - etc/awesome.git/blobdiff - widgets/bat.lua

madduck's git repository

Every one of the projects in this repository is available at the canonical URL git://git.madduck.net/madduck/pub/<projectpath> — see each project's metadata for the exact URL.

All patches and comments are welcome. Please squash your changes to logical commits before using git-format-patch and git-send-email to patches@git.madduck.net. If you'd read over the Git project's submission guidelines and adhered to them, I'd be especially grateful.

SSH access, as well as push access can be individually arranged.

If you use my repositories frequently, consider adding the following snippet to ~/.gitconfig and using the third clone URL listed for each project:

[url "git://git.madduck.net/madduck/"]
  insteadOf = madduck:

Add possibility to give a list of batteries instead of only one.
[etc/awesome.git] / widgets / bat.lua
index 2906de2703db2ca154b138c130bcf11169bde35e..e1bc5d1133839104653b53494da8e9f0ec0b645c 100644 (file)
@@ -1,10 +1,10 @@
 
 --[[
-                                                  
-     Licensed under GNU General Public License v2 
-      * (c) 2013,      Luke Bonham                
-      * (c) 2010-2012, Peter Hofmann              
-                                                  
+                                                                                                                       
+        Licensed under GNU General Public License v2 
+         * (c) 2013,      Luke Bonham                
+         * (c) 2010-2012, Peter Hofmann              
+                                                                                                                       
 --]]
 
 local newtimer     = require("lain.helpers").newtimer
@@ -13,7 +13,7 @@ local first_line   = require("lain.helpers").first_line
 local naughty      = require("naughty")
 local wibox        = require("wibox")
 
-local math         = { floor  = math.floor }
+local math         = { floor  = math.floor, min = math.min }
 local string       = { format = string.format }
 local tonumber     = tonumber
 
@@ -21,118 +21,131 @@ local setmetatable = setmetatable
 
 -- Battery infos
 -- lain.widgets.bat
-local bat = {}
 
 local function worker(args)
-    local args = args or {}
-    local timeout = args.timeout or 30
-    local battery = args.battery or "BAT0"
+    local bat       = {}
+    local args      = args or {}
+    local timeout   = args.timeout or 30
+    local batteries = args.batteries or (args.battery and {args.battery}) or {"BAT0"}
+    local ac        = args.ac or "AC0"
+    local notify    = args.notify or "on"
     local settings = args.settings or function() end
 
     bat.widget = wibox.widget.textbox('')
 
+    bat_notification_low_preset = {
+        title   = "Battery low",
+        text    = "Plug the cable!",
+        timeout = 15,
+        fg      = "#202020",
+        bg      = "#CDCDCD"
+    }
+
+    bat_notification_critical_preset = {
+        title   = "Battery exhausted",
+        text    = "Shutdown imminent",
+        timeout = 15,
+        fg      = "#000000",
+        bg      = "#FFFFFF"
+    }
+
     function update()
         bat_now = {
-            status = "Not present",
-            perc   = "N/A",
-            time   = "N/A",
-            watt   = "N/A"
+            status    = "Not present",
+            ac_status = "N/A",
+            perc      = "N/A",
+            time      = "N/A",
+            watt      = "N/A"
         }
 
-        local bstr  = "/sys/class/power_supply/" .. battery
-
-        local present = first_line(bstr .. "/present")
+        local sum_rate_current = 0
+        local sum_rate_voltage = 0
+        local sum_rate_power = 0
+        local sum_energy_now = 0
+        local sum_energy_full = 0
+        local sum_energy_percentage = 0
 
-        if present == "1"
-        then
-            local rate  = first_line(bstr .. "/power_now") or
-                          first_line(bstr .. "/current_now")
+        for i, battery in ipairs(batteries) do
+            local bstr    = "/sys/class/power_supply/" .. battery
+            local present = first_line(bstr .. "/present")
 
-            local ratev = first_line(bstr .. "/voltage_now")
+            if present == "1"
+            then
+                -- current_now(I)[uA], voltage_now(U)[uV], power_now(P)[uW]
+                local rate_current      = tonumber(first_line(bstr .. "/current_now"))
+                local rate_voltage      = tonumber(first_line(bstr .. "/voltage_now"))
+                local rate_power        = tonumber(first_line(bstr .. "/power_now"))
 
-            local rem   = first_line(bstr .. "/energy_now") or
-                          first_line(bstr .. "/charge_now")
+                -- energy_now(P)[uWh], charge_now(I)[uAh]
+                local energy_now        = tonumber(first_line(bstr .. "/energy_now") or
+                                          first_line(bstr .. "/charge_now"))
 
-            local tot   = first_line(bstr .. "/energy_full") or
-                          first_line(bstr .. "/charge_full")
+                -- energy_full(P)[uWh], charge_full(I)[uAh]
+                local energy_full       = tonumber(first_line(bstr .. "/energy_full") or
+                                          first_line(bstr .. "/charge_full"))
 
-            bat_now.status = first_line(bstr .. "/status") or "N/A"
+                local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
+                                          math.floor((energy_now / energy_full) * 100)
 
-            rate  = tonumber(rate)
-            ratev = tonumber(ratev)
-            rem   = tonumber(rem)
-            tot   = tonumber(tot)
+                if bat_now.status ~= "Charging" and bat_now.status ~= "Discharging"
+                then
+                    bat_now.status = first_line(bstr .. "/status") or "N/A"
+                end
 
-            local time_rat = 0
-            if bat_now.status == "Charging"
-            then
-                time_rat = (tot - rem) / rate
-            elseif bat_now.status == "Discharging"
-            then
-                time_rat = rem / rate
+                sum_rate_current = sum_rate_current + (rate_current or 0)
+                sum_rate_voltage = sum_rate_voltage + rate_voltage
+                sum_rate_power = sum_rate_power + (rate_power or ((rate_voltage * rate_current) / 1e6))
+                sum_energy_now = sum_energy_now + energy_now
+                sum_energy_full = sum_energy_full + energy_full
+                sum_energy_percentage = sum_energy_percentage + energy_percentage
             end
+        end
 
-            local hrs = math.floor(time_rat)
-            if hrs < 0 then hrs = 0 elseif hrs > 23 then hrs = 23 end
-
-            local min = math.floor((time_rat - hrs) * 60)
-            if min < 0 then min = 0 elseif min > 59 then min = 59 end
-
-            bat_now.time = string.format("%02d:%02d", hrs, min)
-
-            local perc = (rem / tot) * 100
-            if perc <= 100 then
-                bat_now.perc = string.format("%d", perc)
-            elseif perc > 100 then
-                bat_now.perc = "100"
-            elseif perc < 0 then
-                bat_now.perc = "0"
-            end
+        local astr    = "/sys/class/power_supply/" .. ac
+        bat_now.ac_status = first_line(astr .. "/online") or "N/A"
 
-            if rate ~= nil and ratev ~= nil then
-                bat_now.watt = string.format("%.2fW", (rate * ratev) / 1e12)
-            else
-                bat_now.watt = "N/A"
+        -- update {perc,time,watt} iff rate > 0 and battery not full
+        if ((sum_rate_current > 0) or (sum_rate_power > 0))
+            and bat_now.status ~= "N/A" and bat_now.status ~= "Full"
+        then
+            local rate_time = 0
+            if bat_now.status == "Charging" then
+                rate_time = (sum_energy_full - sum_energy_now) / (sum_rate_power or sum_rate_current)
+            elseif bat_now.status == "Discharging" then
+                rate_time = sum_energy_now / (sum_rate_power or sum_rate_current)
             end
 
-            -- notifications for low and critical states
-            if bat_now.status == "Discharging"
-            then
-                if tonumber(bat_now.perc) <= 5
-                then
-                    bat.id = naughty.notify({
-                        text = "shutdown imminent",
-                        title = "battery nearly exhausted",
-                        position = "top_right",
-                        timeout = 15,
-                        fg="#000000",
-                        bg="#ffffff",
-                        ontop = true,
-                        replaces_id = bat.id
-                    }).id
-                elseif tonumber(bat_now.perc) <= 15
-                then
-                    bat.id = naughty.notify({
-                        text = "plug the cable",
-                        title = "battery low",
-                        position = "top_right",
-                        timeout = 15,
-                        fg="#202020",
-                        bg="#cdcdcd",
-                        ontop = true,
-                        replaces_id = bat.id
-                    }).id
-                end
-            end
+            local hours   = math.floor(rate_time)
+            local minutes = math.floor((rate_time - hours) * 60)
+            local watt    = sum_rate_power / 1e6
+            bat_now.perc  = string.format("%d", math.min(100, sum_energy_percentage / table.getn(batteries)))
+            bat_now.time  = string.format("%02d:%02d", hours, minutes)
+            bat_now.watt  = string.format("%.2fW", watt)
         end
 
         widget = bat.widget
         settings()
+
+        -- notifications for low and critical states
+        if bat_now.status == "Discharging" and notify == "on" and bat_now.perc then
+            local nperc = tonumber(bat_now.perc) or 100
+            if nperc <= 5 then
+                bat.id = naughty.notify({
+                    preset = bat_notification_critical_preset,
+                    replaces_id = bat.id,
+                }).id
+            elseif nperc <= 15 then
+                bat.id = naughty.notify({
+                    preset = bat_notification_low_preset,
+                    replaces_id = bat.id,
+                }).id
+            end
+        end
     end
 
-    newtimer("bat", timeout, update)
+    newtimer(battery, timeout, update)
 
-    return bat.widget
+    return setmetatable(bat, { __index = bat.widget })
 end
 
-return setmetatable(bat, { __call = function(_, ...) return worker(...) end })
+return setmetatable({}, { __call = function(_, ...) return worker(...) end })