]> git.madduck.net Git - etc/awesome.git/blobdiff - widgets/bat.lua

madduck's git repository

Every one of the projects in this repository is available at the canonical URL git://git.madduck.net/madduck/pub/<projectpath> — see each project's metadata for the exact URL.

All patches and comments are welcome. Please squash your changes to logical commits before using git-format-patch and git-send-email to patches@git.madduck.net. If you'd read over the Git project's submission guidelines and adhered to them, I'd be especially grateful.

SSH access, as well as push access can be individually arranged.

If you use my repositories frequently, consider adding the following snippet to ~/.gitconfig and using the third clone URL listed for each project:

[url "git://git.madduck.net/madduck/"]
  insteadOf = madduck:

weather: icons based on localtime; closes pull #198
[etc/awesome.git] / widgets / bat.lua
index f20034b5e17943f4294c7e47fca3b52e79722117..43b7a5f22102fd0cc54bd0ce2bde021586fc415b 100644 (file)
@@ -1,10 +1,10 @@
 
 --[[
-                                                                                                 
+                                                                                                                       
         Licensed under GNU General Public License v2 
          * (c) 2013,      Luke Bonham                
          * (c) 2010-2012, Peter Hofmann              
-                                                                                                 
+                                                                                                                       
 --]]
 
 local newtimer     = require("lain.helpers").newtimer
@@ -13,7 +13,7 @@ local first_line   = require("lain.helpers").first_line
 local naughty      = require("naughty")
 local wibox        = require("wibox")
 
-local math         = { floor  = math.floor }
+local math         = { floor  = math.floor, min = math.min }
 local string       = { format = string.format }
 local tonumber     = tonumber
 
@@ -23,115 +23,110 @@ local setmetatable = setmetatable
 -- lain.widgets.bat
 
 local function worker(args)
-       local bat      = {}
-       local args     = args or {}
-       local timeout  = args.timeout or 30
-       local battery  = args.battery or "BAT0"
-       local ac       = args.ac or "AC0"
-       local notify   = args.notify or "on"
-       local settings = args.settings or function() end
+    local bat      = {}
+    local args     = args or {}
+    local timeout  = args.timeout or 30
+    local battery  = args.battery or "BAT0"
+    local ac       = args.ac or "AC0"
+    local notify   = args.notify or "on"
+    local settings = args.settings or function() end
 
-       bat.widget = wibox.widget.textbox('')
+    bat.widget = wibox.widget.textbox('')
 
-       bat_notification_low_preset = {
+    bat_notification_low_preset = {
         title   = "Battery low",
-               text    = "Plug the cable!",
-               timeout = 15,
-               fg      = "#202020",
-               bg      = "#CDCDCD"
-       }
-
-       bat_notification_critical_preset = {
-               title   = "Battery exhausted",
-               text    = "Shutdown imminent",
-               timeout = 15,
-               fg      = "#000000",
-               bg      = "#FFFFFF"
-       }
-
-       function update()
-               bat_now = {
-                       status    = "Not present",
-                       ac_status = "N/A",
-                       perc      = "N/A",
-                       time      = "N/A",
-                       watt      = "N/A"
-               }
-
-               local bstr    = "/sys/class/power_supply/" .. battery
-               local astr    = "/sys/class/power_supply/" .. ac
-               local present = first_line(bstr .. "/present")
-
-               if present == "1"
-               then
-                       -- current_now(I)[uA], voltage_now(U)[uV], power_now(P)[uW]
-                       local rate_current      = tonumber(first_line(bstr .. "/current_now"))
-                       local rate_voltage      = tonumber(first_line(bstr .. "/voltage_now"))
-                       local rate_power        = tonumber(first_line(bstr .. "/power_now"))
-
-                       -- energy_now(P)[uWh], charge_now(I)[uAh]
-                       local energy_now        = tonumber(first_line(bstr .. "/energy_now") or
+        text    = "Plug the cable!",
+        timeout = 15,
+        fg      = "#202020",
+        bg      = "#CDCDCD"
+    }
+
+    bat_notification_critical_preset = {
+        title   = "Battery exhausted",
+        text    = "Shutdown imminent",
+        timeout = 15,
+        fg      = "#000000",
+        bg      = "#FFFFFF"
+    }
+
+    function update()
+        bat_now = {
+            status    = "Not present",
+            ac_status = "N/A",
+            perc      = "N/A",
+            time      = "N/A",
+            watt      = "N/A"
+        }
+
+        local bstr    = "/sys/class/power_supply/" .. battery
+        local astr    = "/sys/class/power_supply/" .. ac
+        local present = first_line(bstr .. "/present")
+
+        if present == "1"
+        then
+            -- current_now(I)[uA], voltage_now(U)[uV], power_now(P)[uW]
+            local rate_current      = tonumber(first_line(bstr .. "/current_now"))
+            local rate_voltage      = tonumber(first_line(bstr .. "/voltage_now"))
+            local rate_power        = tonumber(first_line(bstr .. "/power_now"))
+
+            -- energy_now(P)[uWh], charge_now(I)[uAh]
+            local energy_now        = tonumber(first_line(bstr .. "/energy_now") or
                                       first_line(bstr .. "/charge_now"))
 
-                       -- energy_full(P)[uWh], charge_full(I)[uAh],
-                       local energy_full       = tonumber(first_line(bstr .. "/energy_full") or
+            -- energy_full(P)[uWh], charge_full(I)[uAh]
+            local energy_full       = tonumber(first_line(bstr .. "/energy_full") or
                                       first_line(bstr .. "/charge_full"))
 
-
-                       local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
+            local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
                                       math.floor((energy_now / energy_full) * 100)
 
-                       bat_now.status    = first_line(bstr .. "/status") or "N/A"
-                       bat_now.ac_status = first_line(astr .. "/online") or "N/A"
-
-                       -- if rate = 0 or rate not defined skip the round
-                       if      not (rate_power and rate_power > 0) and
-                               not (rate_current and  rate_current > 0) and
-                               not (bat_now.status == "Full")
-                       then
-                               return
-                       end
-
-                       local rate_time = 0
-                       if bat_now.status == "Charging" then
-                           rate_time = (energy_full - energy_now) / rate_power or rate_current
-                       elseif bat_now.status == "Discharging" then
-                           rate_time = energy_now / (rate_power or rate_current)
-                       end
-
-                       local hours   = math.floor(rate_time)
-                       local minutes = math.floor((rate_time - hours) * 60)
-                        
-                        local watt    = rate_power and (rate_power / 1e6) or (rate_voltage * rate_current) / 1e12
-                        
-                       bat_now.perc = string.format("%d", energy_percentage)
-                       bat_now.time = string.format("%02d:%02d", hours, minutes)
-                       bat_now.watt = string.format("%.2fW", watt)
-               end
-
-               widget = bat.widget
-               settings()
-
-               -- notifications for low and critical states
-               if bat_now.status == "Discharging" and notify == "on" and bat_now.perc then
-                       local nperc = tonumber(bat_now.perc) or 100
-                       if nperc <= 5 then
-                               bat.id = naughty.notify({
-                                       preset = bat_notification_critical_preset,
-                                       replaces_id = bat.id,
-                               }).id
-                       elseif nperc <= 15 then
-                               bat.id = naughty.notify({
-                                       preset = bat_notification_low_preset,
-                                       replaces_id = bat.id,
-                               }).id
-                       end
-               end
-       end
-
-       newtimer(battery, timeout, update)
-
-       return setmetatable(bat, { __index = bat.widget })
+            bat_now.status    = first_line(bstr .. "/status") or "N/A"
+            bat_now.ac_status = first_line(astr .. "/online") or "N/A"
+
+            -- update {perc,time,watt} iff rate > 0 and battery not full
+            if ((rate_current and rate_current > 0) or (rate_power and rate_power > 0))
+                and bat_now.status ~= "N/A" and bat_now.status ~= "Full"
+            then
+                local rate_time = 0
+                if bat_now.status == "Charging" then
+                    rate_time = (energy_full - energy_now) / (rate_power or rate_current)
+                elseif bat_now.status == "Discharging" then
+                    rate_time = energy_now / (rate_power or rate_current)
+                end
+
+                local hours   = math.floor(rate_time)
+                local minutes = math.floor((rate_time - hours) * 60)
+                local watt    = rate_power and (rate_power / 1e6) or (rate_voltage * rate_current) / 1e12
+
+                bat_now.perc = string.format("%d", math.min(100, energy_percentage))
+                bat_now.time = string.format("%02d:%02d", hours, minutes)
+                bat_now.watt = string.format("%.2fW", watt)
+            end
+        end
+
+        widget = bat.widget
+        settings()
+
+        -- notifications for low and critical states
+        if bat_now.status == "Discharging" and notify == "on" and bat_now.perc then
+            local nperc = tonumber(bat_now.perc) or 100
+            if nperc <= 5 then
+                bat.id = naughty.notify({
+                    preset = bat_notification_critical_preset,
+                    replaces_id = bat.id,
+                }).id
+            elseif nperc <= 15 then
+                bat.id = naughty.notify({
+                    preset = bat_notification_low_preset,
+                    replaces_id = bat.id,
+                }).id
+            end
+        end
+    end
+
+    newtimer(battery, timeout, update)
+
+    return setmetatable(bat, { __index = bat.widget })
 end
 
 return setmetatable({}, { __call = function(_, ...) return worker(...) end })