]> git.madduck.net Git - etc/awesome.git/blobdiff - widgets/bat.lua

madduck's git repository

Every one of the projects in this repository is available at the canonical URL git://git.madduck.net/madduck/pub/<projectpath> — see each project's metadata for the exact URL.

All patches and comments are welcome. Please squash your changes to logical commits before using git-format-patch and git-send-email to patches@git.madduck.net. If you'd read over the Git project's submission guidelines and adhered to them, I'd be especially grateful.

SSH access, as well as push access can be individually arranged.

If you use my repositories frequently, consider adding the following snippet to ~/.gitconfig and using the third clone URL listed for each project:

[url "git://git.madduck.net/madduck/"]
  insteadOf = madduck:

#199 #203 fix attempt 4
[etc/awesome.git] / widgets / bat.lua
index 6db5d955f91cf019c7857da737a50d0e105ec92c..fa9f85458bf823517902cb0d223861cebc6cdb6d 100644 (file)
@@ -50,7 +50,7 @@ local function worker(args)
     }
 
     bat_now = {
-        status    = "Not present",
+        status    = "N/A",
         ac_status = "N/A",
         perc      = "N/A",
         time      = "N/A",
@@ -59,23 +59,24 @@ local function worker(args)
 
     bat_now.n_status = {}
     for i = 1, #batteries do
-        bat_now.n_status[i] = "Not present"
+        bat_now.n_status[i] = "N/A"
     end
 
     function update()
-        local sum_rate_current = 0
-        local sum_rate_voltage = 0
-        local sum_rate_power = 0
-        local sum_energy_now = 0
-        local sum_energy_full = 0
+        local sum_rate_current      = 0
+        local sum_rate_voltage      = 0
+        local sum_rate_power        = 0
+        local sum_energy_now        = 0
+        local sum_energy_full       = 0
         local sum_energy_percentage = 0
+        local pspath                = "/sys/class/power_supply/"
+  --      local pspath = "/home/luke/Download/"
 
         for i, battery in ipairs(batteries) do
-            local bstr    = "/sys/class/power_supply/" .. battery
+            local bstr    = pspath .. battery
             local present = first_line(bstr .. "/present")
 
-            if present == "1"
-            then
+            if tonumber(present) == 1 then
                 -- current_now(I)[uA], voltage_now(U)[uV], power_now(P)[uW]
                 local rate_current      = tonumber(first_line(bstr .. "/current_now"))
                 local rate_voltage      = tonumber(first_line(bstr .. "/voltage_now"))
@@ -92,59 +93,59 @@ local function worker(args)
                 local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
                                           math.floor((energy_now / energy_full) * 100)
 
-                if bat_now.n_status[i] ~= "Charging" and bat_now.n_status[i] ~= "Discharging"
-                then
-                    bat_now.n_status[i] = first_line(bstr .. "/status") or "N/A"
-                end
+                bat_now.n_status[i] = first_line(bstr .. "/status") or "N/A"
 
                 sum_rate_current      = sum_rate_current + (rate_current or 0)
                 sum_rate_voltage      = sum_rate_voltage + rate_voltage
                 sum_rate_power        = sum_rate_power + (rate_power or ((rate_voltage * rate_current) / 1e6))
-                sum_energy_now        = sum_energy_now + energy_now
+                sum_energy_now        = sum_energy_now + (energy_now or 0)
                 sum_energy_full       = sum_energy_full + energy_full
                 sum_energy_percentage = sum_energy_percentage + energy_percentage
             end
         end
 
         bat_now.status = bat_now.n_status[1]
-        bat_now.ac_status = first_line(string.format("/sys/class/power_supply/%s/online", ac)) or "N/A"
-
-        -- update {perc,time,watt} iff rate > 0 and battery not full
-        if (sum_rate_current > 0 or sum_rate_power > 0)
-           and bat_now.status ~= "N/A" and bat_now.status ~= "Full"
-        then
-            local rate_time = 0
-
-            if bat_now.status == "Charging" then
-                rate_time = (sum_energy_full - sum_energy_now) / (sum_rate_power or sum_rate_current)
-            elseif bat_now.status == "Discharging" then
-                rate_time = sum_energy_now / (sum_rate_power or sum_rate_current)
-            end
-
-            local hours   = math.floor(rate_time)
-            local minutes = math.floor((rate_time - hours) * 60)
-            local watt    = sum_rate_power / 1e6
+        bat_now.ac_status = tonumber(first_line(string.format("%s%s/online", pspath, ac))) or "N/A"
+
+        if bat_now.status ~= "N/A" then
+            -- update {perc,time,watt} iff battery not full and rate > 0
+            if bat_now.status ~= "Full" and (sum_rate_current > 0 or sum_rate_power > 0) then
+                local rate_time = 0
+                local sum_rpc   = sum_rate_power or sum_rate_current
+                if sum_rpc >= 1e8 then sum_rpc = sum_rpc / 10 end
+
+                if bat_now.status == "Charging" then
+                    rate_time = (sum_energy_full - sum_energy_now) / sum_rpc
+                elseif bat_now.status == "Discharging" then
+                    rate_time = sum_energy_now / sum_rpc
+                end
 
-            bat_now.perc  = string.format("%d", math.min(100, sum_energy_percentage / #batteries))
-            bat_now.time  = string.format("%02d:%02d", hours, minutes)
-            bat_now.watt  = string.format("%.2fW", watt)
+                local hours   = math.floor(rate_time)
+                local minutes = math.floor((rate_time - hours) * 60)
+                bat_now.perc  = tonumber(string.format("%d", math.min(100, sum_energy_percentage / #batteries)))
+                bat_now.time  = string.format("%02d:%02d", hours, minutes)
+                bat_now.watt  = tonumber(string.format("%.2f", sum_rate_power / 1e6))
+            elseif bat_now.status == "Full" then
+                bat_now.perc  = 100
+                bat_now.time  = "00:00"
+                bat_now.watt  = 0
+            end
         end
 
         widget = bat.widget
         settings()
 
         -- notifications for low and critical states
-        if bat_now.status == "Discharging" and notify == "on" and bat_now.perc then
-            local nperc = tonumber(bat_now.perc) or 100
-            if nperc <= 5 then
+        if notify == "on" and bat_now.perc and bat_now.status == "Discharging" then
+            if bat_now.perc <= 5 then
                 bat.id = naughty.notify({
                     preset = bat_notification_critical_preset,
-                    replaces_id = bat.id,
+                    replaces_id = bat.id
                 }).id
-            elseif nperc <= 15 then
+            elseif bat_now.perc <= 15 then
                 bat.id = naughty.notify({
                     preset = bat_notification_low_preset,
-                    replaces_id = bat.id,
+                    replaces_id = bat.id
                 }).id
             end
         end