]> git.madduck.net Git - etc/awesome.git/blobdiff - widgets/bat.lua

madduck's git repository

Every one of the projects in this repository is available at the canonical URL git://git.madduck.net/madduck/pub/<projectpath> — see each project's metadata for the exact URL.

All patches and comments are welcome. Please squash your changes to logical commits before using git-format-patch and git-send-email to patches@git.madduck.net. If you'd read over the Git project's submission guidelines and adhered to them, I'd be especially grateful.

SSH access, as well as push access can be individually arranged.

If you use my repositories frequently, consider adding the following snippet to ~/.gitconfig and using the third clone URL listed for each project:

[url "git://git.madduck.net/madduck/"]
  insteadOf = madduck:

lain: wiki updated
[etc/awesome.git] / widgets / bat.lua
index f3fcbdfa266eb837ffdab711733ab4311ba1e3e3..152fa12a626a6ed70eb7f17d6e8521209be436e6 100644 (file)
@@ -1,10 +1,10 @@
 
 --[[
-                                                  
-     Licensed under GNU General Public License v2 
-      * (c) 2013,      Luke Bonham                
-      * (c) 2010-2012, Peter Hofmann              
-                                                  
+                                                                                                                       
+        Licensed under GNU General Public License v2 
+         * (c) 2013,      Luke Bonham                
+         * (c) 2010-2012, Peter Hofmann              
+                                                                                                                       
 --]]
 
 local newtimer     = require("lain.helpers").newtimer
@@ -34,19 +34,19 @@ local function worker(args)
     bat.widget = wibox.widget.textbox('')
 
     bat_notification_low_preset = {
-        title = "Battery low",
-        text = "Plug the cable!",
+        title   = "Battery low",
+        text    = "Plug the cable!",
         timeout = 15,
-        fg = "#202020",
-        bg = "#CDCDCD"
+        fg      = "#202020",
+        bg      = "#CDCDCD"
     }
 
     bat_notification_critical_preset = {
-        title = "Battery exhausted",
-        text = "Shutdown imminent",
+        title   = "Battery exhausted",
+        text    = "Shutdown imminent",
         timeout = 15,
-        fg = "#000000",
-        bg = "#FFFFFF"
+        fg      = "#000000",
+        bg      = "#FFFFFF"
     }
 
     function update()
@@ -59,60 +59,48 @@ local function worker(args)
         }
 
         local bstr    = "/sys/class/power_supply/" .. battery
+        local astr    = "/sys/class/power_supply/" .. ac
         local present = first_line(bstr .. "/present")
 
         if present == "1"
         then
-            local rate = tonumber(first_line(bstr .. "/power_now"))
-            local current_now = false
+            -- current_now(I)[uA], voltage_now(U)[uV], power_now(P)[uW]
+            local rate_current      = tonumber(first_line(bstr .. "/current_now"))
+            local rate_voltage      = tonumber(first_line(bstr .. "/voltage_now"))
+            local rate_power        = tonumber(first_line(bstr .. "/power_now"))
 
-            if not rate then
-                rate = tonumber(first_line(bstr .. "/current_now"))
-                current_now = true
-            end
-
-            local ratev    = tonumber(first_line(bstr .. "/voltage_now"))
-
-            local rem      = tonumber(first_line(bstr .. "/energy_now") or
+            -- energy_now(P)[uWh], charge_now(I)[uAh]
+            local energy_now        = tonumber(first_line(bstr .. "/energy_now") or
                                       first_line(bstr .. "/charge_now"))
 
-            local tot      = tonumber(first_line(bstr .. "/energy_full") or
+            -- energy_full(P)[uWh], charge_full(I)[uAh]
+            local energy_full       = tonumber(first_line(bstr .. "/energy_full") or
                                       first_line(bstr .. "/charge_full"))
 
-            bat_now.status = first_line(bstr .. "/status") or "N/A"
-            bat_now.ac_status = first_line(string.format("/sys/class/power_supply/%s/online", ac)) or "N/A"
-
-            local time_rat = 0
-            if bat_now.status == "Charging"
-            then
-                time_rat = (tot - rem) / rate
-            elseif bat_now.status == "Discharging"
-            then
-                time_rat = rem / rate
-            end
-
-            local hrs = math.floor(time_rat)
-            if hrs < 0 then hrs = 0 elseif hrs > 23 then hrs = 23 end
+            local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
+                                      math.floor((energy_now / energy_full) * 100)
 
-            local min = math.floor((time_rat - hrs) * 60)
-            if min < 0 then min = 0 elseif min > 59 then min = 59 end
+            bat_now.status    = first_line(bstr .. "/status") or "N/A"
+            bat_now.ac_status = first_line(astr .. "/online") or "N/A"
 
-            bat_now.time = string.format("%02d:%02d", hrs, min)
-
-            local perc = tonumber(first_line(bstr .. "/capacity")) or math.floor((rem / tot) * 100)
-
-            if perc <= 100 then
-                bat_now.perc = string.format("%d", perc)
-            elseif perc > 100 then
-                bat_now.perc = "100"
-            elseif perc < 0 then
-                bat_now.perc = "0"
-            end
-
-            if current_now then
-                bat_now.watt = string.format("%.2fW", (rate * ratev) / 1e12)
-            else
-                bat_now.watt = string.format("%.2fW", rate)
+            -- update {perc,time,watt} iff rate > 0 and battery not full
+            if ((rate_current and rate_current > 0) or (rate_power and rate_power > 0))
+                and bat_now.status ~= "N/A" and bat_now.status ~= "Full"
+            then
+                local rate_time = 0
+                if bat_now.status == "Charging" then
+                    rate_time = (energy_full - energy_now) / (rate_power or rate_current)
+                elseif bat_now.status == "Discharging" then
+                    rate_time = energy_now / (rate_power or rate_current)
+                end
+
+                local hours   = math.floor(rate_time)
+                local minutes = math.floor((rate_time - hours) * 60)
+                local watt    = rate_power and (rate_power / 1e6) or (rate_voltage * rate_current) / 1e12
+
+                bat_now.perc = string.format("%d", energy_percentage)
+                bat_now.time = string.format("%02d:%02d", hours, minutes)
+                bat_now.watt = string.format("%.2fW", watt)
             end
         end
 
@@ -120,17 +108,14 @@ local function worker(args)
         settings()
 
         -- notifications for low and critical states
-        if bat_now.status == "Discharging" and notify == "on" and bat_now.perc
-        then
+        if bat_now.status == "Discharging" and notify == "on" and bat_now.perc then
             local nperc = tonumber(bat_now.perc) or 100
-            if nperc <= 5
-            then
+            if nperc <= 5 then
                 bat.id = naughty.notify({
                     preset = bat_notification_critical_preset,
                     replaces_id = bat.id,
                 }).id
-            elseif nperc <= 15
-            then
+            elseif nperc <= 15 then
                 bat.id = naughty.notify({
                     preset = bat_notification_low_preset,
                     replaces_id = bat.id,