]> git.madduck.net Git - etc/awesome.git/blobdiff - widgets/bat.lua

madduck's git repository

Every one of the projects in this repository is available at the canonical URL git://git.madduck.net/madduck/pub/<projectpath> — see each project's metadata for the exact URL.

All patches and comments are welcome. Please squash your changes to logical commits before using git-format-patch and git-send-email to patches@git.madduck.net. If you'd read over the Git project's submission guidelines and adhered to them, I'd be especially grateful.

SSH access, as well as push access can be individually arranged.

If you use my repositories frequently, consider adding the following snippet to ~/.gitconfig and using the third clone URL listed for each project:

[url "git://git.madduck.net/madduck/"]
  insteadOf = madduck:

Merge branch 'master' of https://github.com/MaximeCheramy/lain into MaximeCheramy...
[etc/awesome.git] / widgets / bat.lua
index d3185890d04032cd8e3165b0090278bf245e3a38..e1bc5d1133839104653b53494da8e9f0ec0b645c 100644 (file)
@@ -13,7 +13,7 @@ local first_line   = require("lain.helpers").first_line
 local naughty      = require("naughty")
 local wibox        = require("wibox")
 
-local math         = { floor  = math.floor }
+local math         = { floor  = math.floor, min = math.min }
 local string       = { format = string.format }
 local tonumber     = tonumber
 
@@ -23,114 +23,129 @@ local setmetatable = setmetatable
 -- lain.widgets.bat
 
 local function worker(args)
-       local bat      = {}
-       local args     = args or {}
-       local timeout  = args.timeout or 30
-       local battery  = args.battery or "BAT0"
-       local ac       = args.ac or "AC0"
-       local notify   = args.notify or "on"
-       local settings = args.settings or function() end
+    local bat       = {}
+    local args      = args or {}
+    local timeout   = args.timeout or 30
+    local batteries = args.batteries or (args.battery and {args.battery}) or {"BAT0"}
+    local ac        = args.ac or "AC0"
+    local notify    = args.notify or "on"
+    local settings = args.settings or function() end
 
-       bat.widget = wibox.widget.textbox('')
+    bat.widget = wibox.widget.textbox('')
 
-       bat_notification_low_preset = {
+    bat_notification_low_preset = {
         title   = "Battery low",
-               text    = "Plug the cable!",
-               timeout = 15,
-               fg      = "#202020",
-               bg      = "#CDCDCD"
-       }
-
-       bat_notification_critical_preset = {
-               title   = "Battery exhausted",
-               text    = "Shutdown imminent",
-               timeout = 15,
-               fg      = "#000000",
-               bg      = "#FFFFFF"
-       }
-
-       function update()
-               bat_now = {
-                       status    = "Not present",
-                       ac_status = "N/A",
-                       perc      = "N/A",
-                       time      = "N/A",
-                       watt      = "N/A"
-               }
-
-               local bstr    = "/sys/class/power_supply/" .. battery
-               local astr    = "/sys/class/power_supply/" .. ac
-               local present = first_line(bstr .. "/present")
-
-               if present == "1"
-               then
-                       -- current_now(I)[uA], voltage_now(U)[uV], power_now(P)[uW]
-                       local rate_current      = tonumber(first_line(bstr .. "/current_now"))
-                       local rate_voltage      = tonumber(first_line(bstr .. "/voltage_now"))
-                       local rate_power        = tonumber(first_line(bstr .. "/power_now"))
-
-                       -- energy_now(P)[uWh], charge_now(I)[uAh]
-                       local energy_now        = tonumber(first_line(bstr .. "/energy_now") or
-                                first_line(bstr .. "/charge_now"))
-
-                       -- energy_full(P)[uWh], charge_full(I)[uAh],
-                       local energy_full       = tonumber(first_line(bstr .. "/energy_full") or
-                                first_line(bstr .. "/charge_full"))
-
-
-                       local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
-                                math.floor((energy_now / energy_full) * 100)
-
-                       bat_now.status    = first_line(bstr .. "/status") or "N/A"
-                       bat_now.ac_status = first_line(astr .. "/online") or "N/A"
-
-                       -- if rate = 0 or rate not defined skip the round
-                       if      not (rate_power and rate_power > 0) and
-          not (rate_current and  rate_current > 0) and
-          not (bat_now.status == "Full")
-                       then
-          return
-                       end
-
-                       local rate_time = 0
-                       if bat_now.status == "Charging" then
-          rate_time = (energy_full - energy_now) / (rate_power or rate_current)
-                       elseif bat_now.status == "Discharging" then
-          rate_time = energy_now / (rate_power or rate_current)
-                       end
-
-                       local hours   = math.floor(rate_time)
-                       local minutes = math.floor((rate_time - hours) * 60)
-      local watt    = rate_power and (rate_power / 1e6) or (rate_voltage * rate_current) / 1e12
-
-                       bat_now.perc = string.format("%d", energy_percentage)
-                       bat_now.time = string.format("%02d:%02d", hours, minutes)
-                       bat_now.watt = string.format("%.2fW", watt)
-               end
-
-               widget = bat.widget
-               settings()
-
-               -- notifications for low and critical states
-               if bat_now.status == "Discharging" and notify == "on" and bat_now.perc then
-                       local nperc = tonumber(bat_now.perc) or 100
-                       if nperc <= 5 then
-                               bat.id = naughty.notify({
-                                       preset = bat_notification_critical_preset,
-                                       replaces_id = bat.id,
-                               }).id
-                       elseif nperc <= 15 then
-                               bat.id = naughty.notify({
-                                       preset = bat_notification_low_preset,
-                                       replaces_id = bat.id,
-                               }).id
-                       end
-               end
-       end
-
-  newtimer(battery, timeout, update)
-
-       return setmetatable(bat, { __index = bat.widget })
+        text    = "Plug the cable!",
+        timeout = 15,
+        fg      = "#202020",
+        bg      = "#CDCDCD"
+    }
+
+    bat_notification_critical_preset = {
+        title   = "Battery exhausted",
+        text    = "Shutdown imminent",
+        timeout = 15,
+        fg      = "#000000",
+        bg      = "#FFFFFF"
+    }
+
+    function update()
+        bat_now = {
+            status    = "Not present",
+            ac_status = "N/A",
+            perc      = "N/A",
+            time      = "N/A",
+            watt      = "N/A"
+        }
+
+        local sum_rate_current = 0
+        local sum_rate_voltage = 0
+        local sum_rate_power = 0
+        local sum_energy_now = 0
+        local sum_energy_full = 0
+        local sum_energy_percentage = 0
+
+        for i, battery in ipairs(batteries) do
+            local bstr    = "/sys/class/power_supply/" .. battery
+            local present = first_line(bstr .. "/present")
+
+            if present == "1"
+            then
+                -- current_now(I)[uA], voltage_now(U)[uV], power_now(P)[uW]
+                local rate_current      = tonumber(first_line(bstr .. "/current_now"))
+                local rate_voltage      = tonumber(first_line(bstr .. "/voltage_now"))
+                local rate_power        = tonumber(first_line(bstr .. "/power_now"))
+
+                -- energy_now(P)[uWh], charge_now(I)[uAh]
+                local energy_now        = tonumber(first_line(bstr .. "/energy_now") or
+                                          first_line(bstr .. "/charge_now"))
+
+                -- energy_full(P)[uWh], charge_full(I)[uAh]
+                local energy_full       = tonumber(first_line(bstr .. "/energy_full") or
+                                          first_line(bstr .. "/charge_full"))
+
+                local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
+                                          math.floor((energy_now / energy_full) * 100)
+
+                if bat_now.status ~= "Charging" and bat_now.status ~= "Discharging"
+                then
+                    bat_now.status = first_line(bstr .. "/status") or "N/A"
+                end
+
+                sum_rate_current = sum_rate_current + (rate_current or 0)
+                sum_rate_voltage = sum_rate_voltage + rate_voltage
+                sum_rate_power = sum_rate_power + (rate_power or ((rate_voltage * rate_current) / 1e6))
+                sum_energy_now = sum_energy_now + energy_now
+                sum_energy_full = sum_energy_full + energy_full
+                sum_energy_percentage = sum_energy_percentage + energy_percentage
+            end
+        end
+
+        local astr    = "/sys/class/power_supply/" .. ac
+        bat_now.ac_status = first_line(astr .. "/online") or "N/A"
+
+        -- update {perc,time,watt} iff rate > 0 and battery not full
+        if ((sum_rate_current > 0) or (sum_rate_power > 0))
+            and bat_now.status ~= "N/A" and bat_now.status ~= "Full"
+        then
+            local rate_time = 0
+            if bat_now.status == "Charging" then
+                rate_time = (sum_energy_full - sum_energy_now) / (sum_rate_power or sum_rate_current)
+            elseif bat_now.status == "Discharging" then
+                rate_time = sum_energy_now / (sum_rate_power or sum_rate_current)
+            end
+
+            local hours   = math.floor(rate_time)
+            local minutes = math.floor((rate_time - hours) * 60)
+            local watt    = sum_rate_power / 1e6
+            bat_now.perc  = string.format("%d", math.min(100, sum_energy_percentage / table.getn(batteries)))
+            bat_now.time  = string.format("%02d:%02d", hours, minutes)
+            bat_now.watt  = string.format("%.2fW", watt)
+        end
+
+        widget = bat.widget
+        settings()
+
+        -- notifications for low and critical states
+        if bat_now.status == "Discharging" and notify == "on" and bat_now.perc then
+            local nperc = tonumber(bat_now.perc) or 100
+            if nperc <= 5 then
+                bat.id = naughty.notify({
+                    preset = bat_notification_critical_preset,
+                    replaces_id = bat.id,
+                }).id
+            elseif nperc <= 15 then
+                bat.id = naughty.notify({
+                    preset = bat_notification_low_preset,
+                    replaces_id = bat.id,
+                }).id
+            end
+        end
+    end
+
+    newtimer(battery, timeout, update)
+
+    return setmetatable(bat, { __index = bat.widget })
 end
 
 return setmetatable({}, { __call = function(_, ...) return worker(...) end })