All patches and comments are welcome. Please squash your changes to logical
commits before using git-format-patch and git-send-email to
patches@git.madduck.net.
If you'd read over the Git project's submission guidelines and adhered to them,
I'd be especially grateful.
4 Licensed under GNU General Public License v2
5 * (c) 2013, Luke Bonham
6 * (c) 2010-2012, Peter Hofmann
10 local newtimer = require("lain.helpers").newtimer
11 local first_line = require("lain.helpers").first_line
13 local naughty = require("naughty")
14 local wibox = require("wibox")
16 local math = { floor = math.floor }
17 local string = { format = string.format }
18 local tonumber = tonumber
20 local setmetatable = setmetatable
25 local function worker(args)
27 local args = args or {}
28 local timeout = args.timeout or 30
29 local battery = args.battery or "BAT0"
30 local ac = args.ac or "AC0"
31 local notify = args.notify or "on"
32 local settings = args.settings or function() end
34 bat.widget = wibox.widget.textbox('')
36 bat_notification_low_preset = {
37 title = "Battery low",
38 text = "Plug the cable!",
44 bat_notification_critical_preset = {
45 title = "Battery exhausted",
46 text = "Shutdown imminent",
54 status = "Not present",
61 local bstr = "/sys/class/power_supply/" .. battery
62 local astr = "/sys/class/power_supply/" .. ac
63 local present = first_line(bstr .. "/present")
67 -- current_now(I)[uA], voltage_now(U)[uV], power_now(P)[uW]
68 local rate_current = tonumber(first_line(bstr .. "/current_now"))
69 local rate_voltage = tonumber(first_line(bstr .. "/voltage_now"))
70 local rate_power = tonumber(first_line(bstr .. "/power_now"))
72 -- energy_now(P)[uWh], charge_now(I)[uAh]
73 local energy_now = tonumber(first_line(bstr .. "/energy_now") or
74 first_line(bstr .. "/charge_now"))
76 -- energy_full(P)[uWh], charge_full(I)[uAh],
77 local energy_full = tonumber(first_line(bstr .. "/energy_full") or
78 first_line(bstr .. "/charge_full"))
81 local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
82 math.floor((energy_now / energy_full) * 100)
84 bat_now.status = first_line(bstr .. "/status") or "N/A"
85 bat_now.ac_status = first_line(astr .. "/online") or "N/A"
87 -- if rate = 0 or rate not defined skip the round
88 if not (rate_power and rate_power > 0) and
89 not (rate_current and rate_current > 0) and
90 not (bat_now.status == "Full")
96 if bat_now.status == "Charging" then
97 rate_time = (energy_full - energy_now) / rate_power or rate_current
98 elseif bat_now.status == "Discharging" then
99 rate_time = energy_now / (rate_power or rate_current)
102 local hours = math.floor(rate_time)
103 local minutes = math.floor((rate_time - hours) * 60)
105 local watt = rate_power and (rate_power / 1e6) or (rate_voltage * rate_current) / 1e12
107 bat_now.perc = string.format("%d", energy_percentage)
108 bat_now.time = string.format("%02d:%02d", hours, minutes)
109 bat_now.watt = string.format("%.2fW", watt)
115 -- notifications for low and critical states
116 if bat_now.status == "Discharging" and notify == "on" and bat_now.perc then
117 local nperc = tonumber(bat_now.perc) or 100
119 bat.id = naughty.notify({
120 preset = bat_notification_critical_preset,
121 replaces_id = bat.id,
123 elseif nperc <= 15 then
124 bat.id = naughty.notify({
125 preset = bat_notification_low_preset,
126 replaces_id = bat.id,
132 newtimer(battery, timeout, update)
134 return setmetatable(bat, { __index = bat.widget })
137 return setmetatable({}, { __call = function(_, ...) return worker(...) end })