]> git.madduck.net Git - etc/awesome.git/blob - widgets/bat.lua

madduck's git repository

Every one of the projects in this repository is available at the canonical URL git://git.madduck.net/madduck/pub/<projectpath> — see each project's metadata for the exact URL.

All patches and comments are welcome. Please squash your changes to logical commits before using git-format-patch and git-send-email to patches@git.madduck.net. If you'd read over the Git project's submission guidelines and adhered to them, I'd be especially grateful.

SSH access, as well as push access can be individually arranged.

If you use my repositories frequently, consider adding the following snippet to ~/.gitconfig and using the third clone URL listed for each project:

[url "git://git.madduck.net/madduck/"]
  insteadOf = madduck:

wiki updated
[etc/awesome.git] / widgets / bat.lua
1
2 --[[
3                                                                                                   
4          Licensed under GNU General Public License v2 
5           * (c) 2013,      Luke Bonham                
6           * (c) 2010-2012, Peter Hofmann              
7                                                                                                   
8 --]]
9
10 local newtimer     = require("lain.helpers").newtimer
11 local first_line   = require("lain.helpers").first_line
12
13 local naughty      = require("naughty")
14 local wibox        = require("wibox")
15
16 local math         = { floor  = math.floor }
17 local string       = { format = string.format }
18 local tonumber     = tonumber
19
20 local setmetatable = setmetatable
21
22 -- Battery infos
23 -- lain.widgets.bat
24
25 local function worker(args)
26         local bat      = {}
27         local args     = args or {}
28         local timeout  = args.timeout or 30
29         local battery  = args.battery or "BAT0"
30         local ac       = args.ac or "AC0"
31         local notify   = args.notify or "on"
32         local settings = args.settings or function() end
33
34         bat.widget = wibox.widget.textbox('')
35
36         bat_notification_low_preset = {
37         title   = "Battery low",
38                 text    = "Plug the cable!",
39                 timeout = 15,
40                 fg      = "#202020",
41                 bg      = "#CDCDCD"
42         }
43
44         bat_notification_critical_preset = {
45                 title   = "Battery exhausted",
46                 text    = "Shutdown imminent",
47                 timeout = 15,
48                 fg      = "#000000",
49                 bg      = "#FFFFFF"
50         }
51
52         function update()
53                 bat_now = {
54                         status    = "Not present",
55                         ac_status = "N/A",
56                         perc      = "N/A",
57                         time      = "N/A",
58                         watt      = "N/A"
59                 }
60
61                 local bstr    = "/sys/class/power_supply/" .. battery
62                 local astr    = "/sys/class/power_supply/" .. ac
63                 local present = first_line(bstr .. "/present")
64
65                 if present == "1"
66                 then
67                         -- current_now(I)[uA], voltage_now(U)[uV], power_now(P)[uW]
68                         local rate_current      = tonumber(first_line(bstr .. "/current_now"))
69                         local rate_voltage      = tonumber(first_line(bstr .. "/voltage_now"))
70                         local rate_power        = tonumber(first_line(bstr .. "/power_now"))
71
72                         -- energy_now(P)[uWh], charge_now(I)[uAh]
73                         local energy_now        = tonumber(first_line(bstr .. "/energy_now") or
74                                       first_line(bstr .. "/charge_now"))
75
76                         -- energy_full(P)[uWh], charge_full(I)[uAh],
77                         local energy_full       = tonumber(first_line(bstr .. "/energy_full") or
78                                       first_line(bstr .. "/charge_full"))
79
80
81                         local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
82                                       math.floor((energy_now / energy_full) * 100)
83
84                         bat_now.status    = first_line(bstr .. "/status") or "N/A"
85                         bat_now.ac_status = first_line(astr .. "/online") or "N/A"
86
87                         -- if rate = 0 or rate not defined skip the round
88                         if      not (rate_power and rate_power > 0) and
89                                 not (rate_current and  rate_current > 0) and
90                                 not (bat_now.status == "Full")
91                         then
92                                 return
93                         end
94
95                         local rate_time = 0
96                         if bat_now.status == "Charging" then
97                                 rate_time = (energy_full - energy_now) / rate_power or rate_current
98                         elseif bat_now.status == "Discharging" then
99                                 rate_time = energy_now / rate_power or rate_current
100                         end
101
102                         local hours   = math.floor(rate_time)
103                         local minutes = math.floor((rate_time - hours) * 60)
104
105                         bat_now.perc = string.format("%d", energy_percentage)
106                         bat_now.time = string.format("%02d:%02d", hours, minutes)
107                         bat_now.watt = string.format("%.2fW", rate_power / 1e6 or (rate_voltage * rate_current)  / 1e12)
108                 end
109
110                 widget = bat.widget
111                 settings()
112
113                 -- notifications for low and critical states
114                 if bat_now.status == "Discharging" and notify == "on" and bat_now.perc then
115                         local nperc = tonumber(bat_now.perc) or 100
116                         if nperc <= 5 then
117                                 bat.id = naughty.notify({
118                                         preset = bat_notification_critical_preset,
119                                         replaces_id = bat.id,
120                                 }).id
121                         elseif nperc <= 15 then
122                                 bat.id = naughty.notify({
123                                         preset = bat_notification_low_preset,
124                                         replaces_id = bat.id,
125                                 }).id
126                         end
127                 end
128         end
129
130         newtimer(battery, timeout, update)
131
132         return setmetatable(bat, { __index = bat.widget })
133 end
134
135 return setmetatable({}, { __call = function(_, ...) return worker(...) end })