]> git.madduck.net Git - etc/awesome.git/blob - widgets/bat.lua

madduck's git repository

Every one of the projects in this repository is available at the canonical URL git://git.madduck.net/madduck/pub/<projectpath> — see each project's metadata for the exact URL.

All patches and comments are welcome. Please squash your changes to logical commits before using git-format-patch and git-send-email to patches@git.madduck.net. If you'd read over the Git project's submission guidelines and adhered to them, I'd be especially grateful.

SSH access, as well as push access can be individually arranged.

If you use my repositories frequently, consider adding the following snippet to ~/.gitconfig and using the third clone URL listed for each project:

[url "git://git.madduck.net/madduck/"]
  insteadOf = madduck:

Merge pull request #190 from aajjbb/master
[etc/awesome.git] / widgets / bat.lua
1
2 --[[
3                                                                                                   
4          Licensed under GNU General Public License v2 
5           * (c) 2013,      Luke Bonham                
6           * (c) 2010-2012, Peter Hofmann              
7                                                                                                   
8 --]]
9
10 local newtimer     = require("lain.helpers").newtimer
11 local first_line   = require("lain.helpers").first_line
12
13 local naughty      = require("naughty")
14 local wibox        = require("wibox")
15
16 local math         = { floor  = math.floor }
17 local string       = { format = string.format }
18 local tonumber     = tonumber
19
20 local setmetatable = setmetatable
21
22 -- Battery infos
23 -- lain.widgets.bat
24
25 local function worker(args)
26         local bat      = {}
27         local args     = args or {}
28         local timeout  = args.timeout or 30
29         local battery  = args.battery or "BAT0"
30         local ac       = args.ac or "AC0"
31         local notify   = args.notify or "on"
32         local settings = args.settings or function() end
33
34         bat.widget = wibox.widget.textbox('')
35
36         bat_notification_low_preset = {
37         title   = "Battery low",
38                 text    = "Plug the cable!",
39                 timeout = 15,
40                 fg      = "#202020",
41                 bg      = "#CDCDCD"
42         }
43
44         bat_notification_critical_preset = {
45                 title   = "Battery exhausted",
46                 text    = "Shutdown imminent",
47                 timeout = 15,
48                 fg      = "#000000",
49                 bg      = "#FFFFFF"
50         }
51
52         function update()
53                 bat_now = {
54                         status    = "Not present",
55                         ac_status = "N/A",
56                         perc      = "N/A",
57                         time      = "N/A",
58                         watt      = "N/A"
59                 }
60
61                 local bstr    = "/sys/class/power_supply/" .. battery
62                 local astr    = "/sys/class/power_supply/" .. ac
63                 local present = first_line(bstr .. "/present")
64
65                 if present == "1"
66                 then
67                         -- current_now(I)[uA], voltage_now(U)[uV], power_now(P)[uW]
68                         local rate_current      = tonumber(first_line(bstr .. "/current_now"))
69                         local rate_voltage      = tonumber(first_line(bstr .. "/voltage_now"))
70                         local rate_power        = tonumber(first_line(bstr .. "/power_now"))
71
72                         -- energy_now(P)[uWh], charge_now(I)[uAh]
73                         local energy_now        = tonumber(first_line(bstr .. "/energy_now") or
74                                       first_line(bstr .. "/charge_now"))
75
76                         -- energy_full(P)[uWh], charge_full(I)[uAh],
77                         local energy_full       = tonumber(first_line(bstr .. "/energy_full") or
78                                       first_line(bstr .. "/charge_full"))
79
80
81                         local energy_percentage = tonumber(first_line(bstr .. "/capacity")) or
82                                       math.floor((energy_now / energy_full) * 100)
83
84                         bat_now.status    = first_line(bstr .. "/status") or "N/A"
85                         bat_now.ac_status = first_line(astr .. "/online") or "N/A"
86
87                         -- if rate = 0 or rate not defined skip the round
88                         if      not (rate_power and rate_power > 0) and
89                                 not (rate_current and  rate_current > 0) and
90                                 not (bat_now.status == "Full")
91                         then
92                                 return
93                         end
94
95                         local rate_time = 0
96                         if bat_now.status == "Charging" then
97                            rate_time = (energy_full - energy_now) / (rate_power or rate_current)
98                         elseif bat_now.status == "Discharging" then
99                            rate_time = energy_now / (rate_power or rate_current)
100                         end
101
102                         local hours   = math.floor(rate_time)
103                         local minutes = math.floor((rate_time - hours) * 60)
104                         
105                         local watt    = rate_power and (rate_power / 1e6) or (rate_voltage * rate_current) / 1e12
106                         
107                         bat_now.perc = string.format("%d", energy_percentage)
108                         bat_now.time = string.format("%02d:%02d", hours, minutes)
109                         bat_now.watt = string.format("%.2fW", watt)
110                 end
111
112                 widget = bat.widget
113                 settings()
114
115                 -- notifications for low and critical states
116                 if bat_now.status == "Discharging" and notify == "on" and bat_now.perc then
117                         local nperc = tonumber(bat_now.perc) or 100
118                         if nperc <= 5 then
119                                 bat.id = naughty.notify({
120                                         preset = bat_notification_critical_preset,
121                                         replaces_id = bat.id,
122                                 }).id
123                         elseif nperc <= 15 then
124                                 bat.id = naughty.notify({
125                                         preset = bat_notification_low_preset,
126                                         replaces_id = bat.id,
127                                 }).id
128                         end
129                 end
130         end
131
132         newtimer(battery, timeout, update)
133
134         return setmetatable(bat, { __index = bat.widget })
135 end
136
137 return setmetatable({}, { __call = function(_, ...) return worker(...) end })